Netgear Switch M4100-12G-POE+ User Manual Page 709

  • Download
  • Add to my manuals
  • Print
  • Page
    / 768
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 708
Log Messages
709
ProSafe M4100 and M7100 Managed Switches
Core
Table 3. BSP Log Messages
Component Message Cause
BSP
Event(0xaaaaaaaa) Switch has restarted.
BSP
Starting code... BSP initialization complete, starting 7000
series application.
Table 4. NIM Log Messages
Component Message Cause
NIM
NIM: L7_ATTACH out of order for
intIfNum(x) unit x slot x port x
Interface creation out of order
NIM
NIM: Failed to find interface at unit x slot x
port x for event(x)
There is no mapping between the USP and
Interface number
NIM
NIM: L7_DETACH out of order for
intIfNum(x) unit x slot x port x
Interface creation out of order
NIM
NIM: L7_DELETE out of order for
intIfNum(x) unit x slot x port x
Interface creation out of order
NIM
NIM: event(x),intf(x),component(x), in
wrong phase
An event was issued to NIM during the
wrong configuration phase (probably Phase
1, 2, or WMU)
NIM
NIM: Failed to notify users of interface
change
Event was not propagated to the system
NIM
NIM: failed to send message to NIM
message Queue.
NIM message queue full or non-existent
NIM
NIM: Failed to notify the components of
L7_CREATE event
Interface not created
NIM
NIM: Attempted event (x), on USP x.x.x
before phase 3
A component issued an interface event
during the wrong initialization phase
NIM
NIM: incorrect phase for operation An API call was made during the wrong
initialization phase
NIM
NIM: Component(x) failed on event(x) for
intIfNum(x)
A component responded with a fail
indication for an interface event
NIM
NIM: Timeout event(x), intIfNum(x)
remainingMask = “xxxx”
A component did not respond before the
NIM timeout occurred
Page view 708
1 2 ... 704 705 706 707 708 709 710 711 712 713 714 ... 767 768

Comments to this Manuals

No comments