Netgear Switch M4100-12G-POE+ User Manual Page 236

  • Download
  • Add to my manuals
  • Print
  • Page
    / 768
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 235
Routing
Interface Status
Primary IP
Address
Secondary IP
Address
Method
Routing Mode
Administrative
Mode
Forward Net
Directed
Broadcasts
Proxy ARP
Local Proxy
ARP
Active State
Link Speed Data
Rate
MAC Address
Encapsulation
Type
IP MTU
Bandwidth
Destination
Unreachables
ICMP Redirects
Routing Commands
236
ProSafe M4100 and M7100 Managed Switches
The following shows example CLI display output for the command.
(Switch) >show ip interface 0/2
Routing Interface Status....................... Down
Method......................................... None
Routing Mode................................... Disable
Administrative Mode............................ Enable
Forward Net Directed Broadcasts................ Disable
Proxy ARP...................................... Enable
Local Proxy ARP................................ Disable
Active State................................... Inactive
Term Definition
Determine the operational status of IPv4 routing Interface. The possible values are Up or
Down.
The primary IP address and subnet masks for the interface. This value appears only if
you configure it.
One or more secondary IP addresses and subnet masks for the interface. This value
appears only if you configure it.
Shows whether the IP address was configured manually or acquired from a DHCP
server
.
The administrative mode of router interface participation. The possible values are enable
or disable.
This value is configurable.
The administrative mode of the specified interface. The possible values of this field are
enable or disable.
This value is configurable.
Displays whether forwarding of network-directed broadcasts is enabled or disabled. This
value is configurable.
Displays whether Proxy ARP is enabled or disabled on the system.
Displays whether Local Proxy ARP is enabled or disabled on the interface.
Displays whether the interface is active or inactive. An interface is considered active if its
link is up and it is in forwarding state.
An integer representing the physical link data rate of the specified interface. This is
measured in Megabits per second (Mbps).
The burned in physical address of the specified interface. The format is 6 two-digit
hexadecimal numbers that are separated by colons.
The encapsulation type for the specified interface. The types are: Ethernet or SNAP.
The maximum transmission unit (MTU) size of a frame, in bytes.
Shows the bandwidth of the interface.
Displays whether ICMP Destination Unreachables might be sent (enabled or disabled).
Displays whether ICMP Redirects might be sent (enabled or disabled).
Page view 235