Utility Commands
531
ProSafe M4100 and M7100 Managed Switches
Note: If you issue the show running-config command from a serial
connection, access to the switch through remote connections (such
as Telnet) is suspended while the output is being generated and
displayed.
Note: If you use a text-based configuration file, the show
running-config command will only display configured physical
interfaces, that is, if any interface only contains the default
configuration, that interface will be skipped from the show
running-config command output. This is true for any
configuration mode that contains nothing but default configuration.
That is, the command to enter a particular config mode, followed
immediately by its ‘exit’ command, are both omitted from the show
running-config command output (and hence from the
startup-config file when the system configuration is saved.)
If all the flags in a particular group are enabled, the command displays trapflags <group
name> all.
If some, but not all, of the flags in that group are enabled, the command displays trapflags
<groupname> <flag-name>.
Format show running-config [all | <scriptname>]
Mode
show running-config interface
This command shows the current configuration on a particular interface. The interface could
be a physical port or a virtual port—like a LAG or VLAN. The output captures how the
configuration differs from the factory default value.
Format
Mode
show sysinfo
This command displays switch information.
Format show sysinfo
Mode
Privileged EXEC
show running-config interface {<slot/port>} | VLAN <id> | LAG <id>}
Interface Config
Privileged EXEC