Netgear GS728TP User Manual Page 133

  • Download
  • Add to my manuals
  • Print
  • Page
    / 530
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 132
Configuring Switching Information
133
ProSafe M5300 Switch
GARP Port Configuration
Note: It can take up to 10 seconds for GARP configuration changes to take
effect.
To display the GARP Port Configuration page, click Switching
VLAN Advanced GARP
Port Configuration.
To configure the per-interface GARP settings:
1. Select the check box associated with each Interface to configure, or select the check box in
the header row to apply the same settings to all interfaces.
2. Use Port GVRP Mode to choose the GARP VLAN Registration Protocol administrative
mode for the port by selecting enable or disable from the dropdown list. If you select disable,
the protocol will not be active and the Join Time, Leave Time and Leave All Time will have
no effect. The factory default is disable.
3. Use Port GMRP Mode to choose the GARP Multicast Registration Protocol administrative
mode for the port by selecting enable or disable from the dropdown list. If you select disable,
the protocol will not be active, and Join Time, Leave Time and Leave All Time have no
effect. The factory default is disable.
4. Use Join Time (centiseconds) to specify the time between the transmission of GARP
PDUs registering (or re-registering) membership for a VLAN or multicast group in
centiseconds. Enter a number between 10 and 100 (0.1 to 1.0 seconds). The factory default
is 20 centiseconds (0.2 seconds). An instance of this timer exists for each GARP participant
for each port.
5. Use Leave Time (centiseconds) to specify the time to wait after receiving an unregister
request for a VLAN or multicast group before deleting the associated entry, in centiseconds.
This allows time for another station to assert registration for the same attribute in order to
maintain uninterrupted service. Enter a number between 20 and 600 (0.2 to 6.0 seconds).
The factory default is 60 centiseconds (0.6 seconds). An instance of this timer exists for
each GARP participant for each port.
Page view 132
1 2 ... 128 129 130 131 132 133 134 135 136 137 138 ... 529 530

Comments to this Manuals

No comments