Configuring Switching Information
138
ProSafe M5300 Switch
OUI Table
Use this page to add and remove Organizationally Unique Identifiers (OUIs) from the OUI
database the device maintains. Device hardware manufacturers can include an OUI in a
network adapter to help identify the device. The OUI is a unique 24-bit number assigned by
the IEEE registration authority. Several default OUIs have been preconfigured in the OUI
database on the device.
To display the OUI Table page, click Switching
Auto-VoIP > OUI-based > OUI Table.
To configure entries in the OUI table:
1. In the Telephony OUI field, specify the unique OUI that identifies the device manufacturer or
vendor. The OUI is specified in three octet values (each octetis represented as two
hexadecimal digits) separated by colons.
2. In the Description field, provide a description of the manufacturer or vendor associated with
the OUI.
3. Click APPLY to update the switch with the changes.
4. Click CANCEL to abandon the changes.
5. To remove an OUI from the table, select the check box next to each entry to remove and
click DELETE.