Using the Command-Line Interface
12
ProSafe Managed Switch
Name with Spaces” forces the system to accept the spaces. Empty strings (““) are not valid
user-defined strings. Table 2 describes common parameter values and value formatting.
Table 2. Parameter Descriptions
a (32 bits)
a.b (8.24 bits)
a.b.c (8.8.16 bits)
0xn (CLI assumes hexadecimal format)
0n (CLI assumes octal format with leading zeros)
Unit/Slot/Port Naming Convention
Managed switch software references physical entities such as cards and ports by using a
unit/slot/port naming convention. The software also uses this convention to identify certain
logical entities, such as Port-Channel interfaces.
The slot number has two uses. In the case of physical ports, it identifies the card containing
the ports. In the case of logical and CPU ports it also identifies the type of interface or port.
Table 3. Type of Slots
Parameter Description
ipaddr This parameter is a valid IP address. You can enter the IP address in the following formats:
a.b.c.d (8.8.8.8)
In addition to these formats, the CLI accepts decimal, hexadecimal and octal formats
through the following input formats (where n is any valid hexadecimal, octal or decimal
number):
n (CLI assumes decimal format)
ipv6-address
FE80:0000:0000:0000:020F:24FF:FEBF:DBCB, or
FE80:0:0:0:20F:24FF:FEBF:DBCB, or
FE80::20F24FF:FEBF:DBCB, or
FE80:0:0:0:20F:24FF:128:141:49:32
For additional information, refer to RFC 3513.
Interface or
unit/slot/port
Valid slot and port number separated by forward slashes. For example, 0/1 represents slot
number 0 and port number 1.
Logical Interface
Represents a logical slot and port number. This is applicable in the case of a port-channel
(LAG). You can use the logical unit/slot/port to configure the port-channel.
Character strings Use double quotation marks to identify character strings, for example, “System Name with
Spaces”. An empty string (“”) is not valid.
Slot Type Description
Physical slot numbers Physical slot numbers begin with zero, and are allocated up to the maximum
number of physical slots.
Logical slot numbers Logical slots immediately follow physical slots and identify port-channel (LAG) or
router interfaces.
CPU slot numbers The CPU slots immediately follow the logical slots.