GS752TXS Smart Switch Software Administration Manual
Interface Naming Convention
The GS752TXS Smart Switch supports physical and logical interfaces. Interfaces are
identified by their type and the interface number. All the physical ports 1–48 are Gigabit ports
and Port 49–52 are SFP+ ports that support both 10G and 1000M mode. The number of the
port is identified on the front panel. You can configure the logical interfaces by using the
software. The following table describes the naming convention for all interfaces available on
the switch.
Interface Description Example
Physical The physical ports include Gigabit ports and are numbered
sequentially starting from one using the following format:
X/gY or X/xgY. X for the unit ID, g is for a 1G port, xg is for a
10G port, and Y is the port number.
1/g1, 1/g2, 2/g3
Link Aggregation Group (LAG) LAG interfaces are logical interfaces that are only used for
bridging functions.
l1, l2, l3
CPU Management Interface This is the internal switch interface responsible for the
switch base MAC address. This interface is not
configurable and is always listed in the MAC Address
Table.
c1