In the following screen, ports 6, 7, and 8 are being added as tagged members to VLAN 2.
6. From the Group Operations list, select an identical configuration for all the ports.
The possible values are:
T
ag All. All frames transmitted for this VLAN are tagged. All the ports are included in
the VLAN.
Untag All.
All frames transmitted from this VLAN are untagged. All the ports are
included in the VLAN.
Remove All. Exclude all ports from the selected VLAN.
7. Click APPL
Y to send the updated configuration to the switch.
Configuration changes take effect immediately.
Port VLAN ID Configuration
The Port PVID Configuration screen lets you assign a port VLAN ID (PVID) to an interface. A
PVID has the following requirements:
All ports must have a defined PVID.
If no other value is specified, the default VLAN PVID is used.
If you want to change the port’
s default PVID, you must first create a VLAN that includes
the port as a member.
Use the Port VLAN ID (PVID) Configuration screen to configure a virtual LAN on a port.