GS752TP, GS728TP, and GS728TPP Gigabit Smart Switches
Green Ethernet Interface Configuration
Using the Green Ethernet Interface Configuration feature allows for proper port configuration
and the ability to enable or disable the Auto Power Down, Short Cable, and EEE Modes on
specific ports.
To configure the Green Ethernet Interface feature:
1. Select System Management Green Ethernet Green Ethernet Interface
Configuration.
The following screen displays:
2. Select the following interface settings for the physical port:
Go To Interface. Enter a port identifier (appears in the Port column) and click the Go
button.
The table entry corresponding to the specified port is selected.
Port. Selects the interface for which data is displayed or configured.
Auto Power Down Mode. Determines whether Auto Power Down mode is enabled
for the port. The factory default is Disable. When the port link is down, the PHY
automatically goes down for a short period and wakes up to check link pulses. This
mode allows automatic negotiation and reduces power consumption when no link
partner is present.
Short Cable Mode. Determines whether Short Cable mode is enabled for the port.
The factory default is Disable. When the port link up at 1 Gbps, the cable length test is
performed. If the length of the cable is less than 10 meters, PHYs are put into
low-power mode so enough power is used to support a short cable. Do not enable
both EEE and Short Cable modes for a port.
EEE Mode. Determines whether Energy Efficient Ethernet (EEE) mode is enabled for
the port. Do not enable both EEE and Short Cable modes for a port.
3. Click APPLY to apply the change to the system.