Chapter 6: Monitoring the System | 215
GS716Tv2 and GS724Tv3 Software Administration Manual
The Memory Log table also appears on the Memory Log page.
The rest of the page displays the Memory Log messages. The format of the log message is
the same for messages that are displayed for the message log, persistent log, or console log.
Messages logged to a collector or relay via syslog have the same format as well.
The following example shows the standard format for a log message:
<14> Mar 24 05:34:05 10.131.12.183-1 UNKN[2176789276]:
main_login.c(179) 3855 %% HTTP Session 19 initiated for user admin
connected from 10.27.64.122
The number contained in the angle brackets represents the message priority, which is
derived from the following values:
Priority = (facility value × 8) + severity level.
The facility value is usually one, which means it is a user-level message. Therefore, to
determine the severity level of the message, subtract eight from the number in the angle
brackets. The example log message has a severity level of 6 (informational). For more
information about the severity of a log message, see the Severity Filter description on page
218.
The message was generated on March 24 at 5:34:05 a.m by the switch with an IP address of
10.131.12.183. The component that generated the message is unknown, but it came from
line 179 of the main_login.c file. This is the 3,855
th
message logged since the switch was last
booted. The message indicates that the administrator logged onto the HTTP management
interface from a host with an IP address of 10.27.64.122.
Use the buttons at the bottom of the page to perform the following actions:
Click Clear to clear the messages out of the buffered log in the memory.
Click Refresh to update the page with the latest messages in the log.
Click Cancel to cancel the configuration on the screen and reset the data on the screen
to the latest value of the switch.
FLASH Log Configuration
The FLASH log is a log that is stored in persistent storage, which means that the log
messages are retained across a switch reboot.
The first log type is the system startup log. The system startup log stores the first N
messages received after system reboot. This log always has the log full operation
attribute set to stop on full and can store up to 32 messages.
Field Description
Total Number of Messages Displays the number of messages the system has logged in memory.
Only the 64 most recent entries are displayed on the page.