User Manual for the NETGEAR 7300S Series Layer 3 Managed Switch Software
8-26 Switching Commands
202-10088-01, March 2005
Allow New Telnet Sessions Indicates that new telnet sessions will not be allowed when
set to no. The factory default value is yes.
show serial
This command displays serial communication settings for the switch.
Format
show serial
Mode Privileged EXEC and User EXEC
Serial Port Login Timeout (minutes) Specifies the time, in minutes, of inactivity on a
Serial port connection, after which the Switch will close the con-
nection. Any numeric value between 0 and 160 is allowed, the
factory default is 5. A value of 0 disables the timeout.
Baud Rate The default baud rate at which the serial port will try to connect.
The available values are 1200, 2400, 4800, 9600, 19200,
38400,57600, and 115200 baud. The factory Default is 9600
baud.
Character Size The number of bits in a character. The number of bits is always 8.
Flow Control Whether Hardware Flow-Control is enabled or disabled. Hard-
ware Flow Control is always disabled.
Stop Bits The number of Stop bits per character. The number of Stop bits is
always 1.
Parity Type The Parity Method used on the Serial Port. The Parity Method is
always None.
show serviceport
This command displays service port configuration information.
Format
show serviceport
Mode Privileged EXEC
IP Address The IP address of the interface. The factory default value is
0.0.0.0
Subnet Mask The IP subnet mask for this interface. The factory default value is
0.0.0.0
Default Gateway The default gateway for this IP interface. The factory default
value is 0.0.0.0