7-18 Monitoring the Switch
v1.1, September 2009
The RMON History Table screen contains the following fields:
History Entry
History Entry No. – Select the entry number for the History Control Table screen.
Owner – Displays the RMON station or user that requested the RMON information. The
field range is 0-20 characters.
History Table
Sample No. – Displays the sample number from which the statistics were taken.
Drop Events – Displays the number of dropped events that have occurred on the interface
since the device was last refreshed.
Received Bytes – Displays the number of octets received on the interface since the device
was last refreshed. This number includes bad packets and FCS octets, but excludes
framing bits.
Received Packets – Displays the number of packets received on the interface since the
device was last refreshed, including bad packets, Multicast, and Broadcast packets.