Reference Manual for the NETGEAR ProSafe Wireless Access Point 802.11g WG302
Basic Installation and Configuration 3-27
July 2005 v3.0
3.
Enter the Radius settings.
Authentication/Access Control Radius Server Configuration: This configuration is
required for authentication using Radius. IP Address, Port No. and Shared Secret is
required for communication with Radius Server. A Secondary Radius Server can be
configured which is used on failure on Primary Radius Server
IP Address: The IP address of the Radius Server. The default is 0.0.0.0.
Port Number: Port number of the Radius Server. The default is 1812.
Shared Secret: This is shared between the Wireless Access Point and the Radius Server
while authenticating the supplicant.
Re-authentication Time: The time interval in seconds after which the supplicant will be
authenticated again with the Radius Server. The default is 3600 seconds.
Global-key Re-Key Time: Check on this option to enable Re-keying of Global Key. The
Global Key Re-Key can be done based on time interval in seconds or number of packets
exchanged using the global key. The default is 3600 seconds.
Update if any station disassociates: Check on this option to refresh global key when any
stations disassociated with wireless Access Point.
Accounting Radius Server Configuration: This configuration is required for accounting
using Radius Server. IP Address, Port No. and Shared Secret is required for
communication with Radius Server. A Secondary Radius Server can be configured which
is used on failure on Primary Radius Server.
IP Address: The IP address of the Radius Server. The default is 0.0.0.0.
Port Number: Port number of the Radius Server. The default is 1813.
Shared Secret: This is shared between the Wireless Access Point and the Radius Server
while authenticating the supplicant.
4. Click Apply to save your settings.