Netgear ProSafe FSM7352S User Manual

Browse online or download User Manual for Network switches Netgear ProSafe FSM7352S. Netgear ProSafe FSM7352S User's Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 24
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
© 2005 by NETGEAR, Inc. All rights reserved.
Trademarks
© 2005 NETGEAR, Inc. NETGEAR ® , the Netgear Logo, the Gear Guy, and Everybody’s connecting are trademarks or registered trademark of
Netgear, Inc. in the United States and/or other countries. Microsoft, Windows, and the Windows logo are trademarks, or registered trademarks of
Microsoft Corporation in the United States and/or other countries. Other brand and Product names are trademarks or registered trademarks of their
respective holders. Information is subject to change without notice. All rights reserved.
Statement of Conditions
In the interest of improving internal design, operational function, and/or reliability, NETGEAR reserves the right to make changes to the products
described in this document without notice. NETGEAR does not assume any liability that may occur due to the use or application of the product(s) or
circuit layout(s) described herein.
Certificate of the Manufacturer/Importer
It is hereby certified that the NETGEAR Model FSM7352S Managed Fast Ethernet Switch has been suppressed in accordance with the conditions
set out in the BMPT-AmtsblVfg 243/1991 and Vfg 46/1992.The operation of some equipment (for example, test transmitters) in accordance with the
regulations may, however, be subject to certain restrictions. Please refer to the notes in the operating instructions.
Federal Office for Telecommunications Approvals has been notified of the placing of this equipment on the market and has been granted the right
to test the series for compliance with the regulations.
Voluntary Control Council for Interference (VCCI) Statement
This equipment is in the first category (information equipment to be used in commercial and/or industrial areas) and conforms to the standards set
by the Voluntary Control Council for Interference by Data Processing Equipment and Electronic Office Machines that are aimed at preventing radio
interference in commercial and/or industrial areas.
Consequently, when this equipment is used in a residential area or in an adjacent area thereto, radio interference may be caused to equipment
such as radios and TV receivers.
Federal Communications Commission (FCC) Compliance Notice: Radio Frequency Notice
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
This device may not cause harmful interference.
This device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and
can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
EN 55 022 Declaration of Conformance
This is to certify that the NETGEAR Model FSM7352S Managed Fast Ethernet Switch is shielded against the generation of radio interference in
accordance with the application of Council Directive 89/336/EEC, Article 4a. Conformity is declared by the application of EN 55024 Class A (CISPR
22).
EN 55 022 and EN 55 024 Statements
This is to certify that the NETGEAR Model FSM7352S Managed Fast Ethernet Switch is shielded against the generation of radio interference in
accordance with the application of Council Directive 89/336/EEC, Article 4a. Conformity is declared by the application of EN 55 022 Class A
(CISPR 22) and EN 55 024.
Page 1 of 24
Page view 0
1 2 3 4 5 6 ... 23 24

Summary of Contents

Page 1

© 2005 by NETGEAR, Inc. All rights reserved. Trademarks © 2005 NETGEAR, Inc. NETGEAR ® , the Netgear Logo, the Gear Guy, and Everybody’s connecting a

Page 2

establish a link with non-stacking interfaces no traffic will pass across the interface. These interfaces are available to quickly and easily build a

Page 3 - CONTENTS

LED Descriptions The front panel of the NETGEAR Model FSM7352S Layer 3 Managed Stackable Fast Ethernet Switch has LEDs that provide a quick and accura

Page 4 - Figures

The console port is configured to use the following settings: • Baud rate: 9,600 bps • Data bits: 8 • Parity: none • Stop bit: 1 • Flow control:

Page 5 - CHAPTER 1: INTRODUCTION

CHAPTER 3: INSTALLATION This chapter describes the installation procedures for your NETGEAR Model FSM7352S Layer 3 Managed Stackable Fast Ethernet Sw

Page 6 - Features

Step 2: Installing the Switch You can install your NETGEAR Model FSM7352S Layer 3 Managed Stackable Fast Ethernet Switch on a flat surface or in a sta

Page 7 - Package Contents

1. Connect the female end of the supplied AC power adapter cable to the power receptacle on the back of the switch. 2. Connect the 3-pronged end of

Page 8

To install additional Gigabit Ethernet module, repeat this procedure Figure 3-3. Installing a Gigabit Ethernet fiber Module into an FSM7352S St

Page 9 - 10/100/1000 Mbps RJ-45 Ports

Figure 3-4. System Information. 5. The login name is “admin”. And there is no password assigned. We strongly recommend you enable password for admi

Page 10 - SFP module bay

Sysinfo page. To use your web browser, simply type the IP address in the URL address bar and hit enter. If you want to use an SNMP management applic

Page 11 - Console Port

APPENDIX A: TECHNICAL SPECIFICATIONS This appendix provides technical specifications for the NETGEAR Model FSM7352S Layer 3 Managed Stackable Fast Eth

Page 12

Warning: This is a Class A product. In a domestic environment, this product may cause radio interference, in which case the user may be required to t

Page 13 - CHAPTER 3: INSTALLATION

Secured Shell (SSHv1,v2) Interface 48 RJ-45 connectors for 10BASE-T and 100BASE-TX (Auto Uplink™ on all ports) 4 RJ-45 connectors for 10BASE-T, 100B

Page 14 - Step 4: Applying AC Power

EN 55024 Safety CE mark, commercial CSA certified (CSA 22.2 #950) UL listed (UL 1950)/cUL IEC950/EN60950 Page 21 of 24

Page 15

APPENDIX B: TROUBLESHOOTING This chapter provides information about troubleshooting the NETGEAR Model FSM7352S Layer 3 Managed Stackable Fast Ethernet

Page 16

Configuration If problems occur after altering the network configuration, restore the original connections and determine the problem by implementing t

Page 17

APPENDIX C: Default Settings This appendix provides the default settings for the NETGEAR Model FSM7352S Layer 3 Managed Stackable Fast Ethernet Switc

Page 18

CONTENTS CHAPTER 1: INTRODUCTION...

Page 19

Figures FIGURE 1-1. PACKAGE CONTENTS...

Page 20

CHAPTER 1: INTRODUCTION Congratulations on your purchase of a NETGEAR Model FSM7352S Layer 3 Managed Stackable Fast Ethernet Switch! Your NETGEAR Swit

Page 21

Features The following list identifies the key features of the NETGEAR Model FSM7352S Layer 3 Managed Stackable Fast Ethernet Switch. • Forty-eight 1

Page 22 - APPENDIX B: TROUBLESHOOTING

o Full-duplex IEEE 802.3x pause frame flow control • Multiple interfaces to access the management features o Browser-based Graphical User Interface

Page 23

Figure 1-1. Package Contents Verify that your package contains the following: FSM7352S Layer 3 Managed Stackable Fast Ethernet Switch Rubber foot

Page 24 - APPENDIX C: Default Settings

CHAPTER 2: PHYSICAL DESCRIPTION This chapter describes the hardware features of the NETGEAR Model FSM7352S Layer 3 Managed Stackable Fast Ethernet Swi