Netgear XSM7224S User Manual Page 136

  • Download
  • Add to my manuals
  • Print
  • Page
    / 579
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 135
ProSafe XSM7224S Managed Stackable Switch CLI Manual, Software Version 9.0
Switching Commands 3-95
v1.0, November 2010
shares traffic based upon the source and destination MAC address.Assign the port-channel (LAG)
VLAN membership after you create a port-channel. If you do not assign VLAN membership, the
port-channel might become a member of the management VLAN which can result in learning and
switching issues.
A port-channel (LAG) interface can be either static or dynamic, but not both. All members of a
port channel must participate in the same protocols.) A static port-channel interface does not
require a partner system to be able to aggregate its member ports.
addport
This command adds one port to the port-channel (LAG). The interface is a logical unit/slot/port
number or a group ID of a configured port-channel.
deleteport (Interface Config)
This command deletes the port from the port-channel (LAG). The interface is a logical unit/slot/
port number or a group ID of a configured port-channel.
Note: If you configure the maximum number of dynamic port-channels (LAGs) that your
platform supports, additional port-channels that you configure are automatically
static.
Note: Before adding a port to a port-channel, set the physical mode of the port. For more
information, see “speed” on page 3-7
Format addport {<logical unit/slot/port>|<lag-group-id>}
Mode Interface Config
Format deleteport {<logical unit/slot/port>|<lag-group-id>}
Mode Interface Config
Page view 135
1 2 ... 131 132 133 134 135 136 137 138 139 140 141 ... 578 579

Comments to this Manuals

No comments