Model EN104TP/EN106TP/EN108TP Ethernet Hub Installation Guide
To complete the installation, connect the power cord rst to the power receptacle
on the hub rear panel and then to the power outlet on the wall. When power has
been applied to the hub:
The green Pwr (Power) LED on the front panel is on.
The green Link LED on each connected port is on.
If there are any problems, refer to Troubleshooting Information.
Refer to this table and the information that follows the table to troubleshoot your
hub.
Network Interface Cards
Make sure the network interface cards installed in the workstations are in
working condition and the software driver has been installed.
Symptom Cause Solution
Amber Col
LED blinks.
Collisions are
occurring on
the network.
Data collision is normal on Ethernet networks. No action
is required.
Amber Col
LED blinks
quickly.
Collisions are
occurring on
the network,
because the
network is
busy or is
defective
devices are
connected on
the network.
Make sure connected devices are operating in half-
duplex mode. The hub is not compatible with devices that
operate in full-duplex mode.
If you suspect that there might be a defective device on
the network, disconnect devices one at a time to isolate
the defective unit on the network.
If the network is extremely busy, you may have to
segment the network with an Ethernet switch such as a
NETGEAR Ethernet switch or to upgrade your network to
Fast Ethernet operation.
Wrong or
miswired
cables are
used.
Make sure the correct UTP cables are used. See the
table in the installation section of this guide for cable use
and Normal/Uplink push button information. Note that
home telephone cables can cause a collision condition
and cannot be used in place of UTP cables.
Green Link
LED is off
when a cable
is attached.
The port is
not detecting
a successful
link.
Check for a bad cable, cable pairs that are not correctly
wired, or loose connectors. Make sure that there is power
to both the hub and the Ethernet transceiver on the
connected device. Make sure the port has not been
partitioned.
Green Rx
LED is off
when data is
transmitting.
The port is
not detecting
data
transmission.
Check for a bad cable, cable pairs that are not correctly
wired, or loose connectors. Make sure that there is power
to both the hub and the Ethernet transceiver on the
connected device. Make sure the port has not been
partitioned.
Verify the Installation
Troubleshooting