Netgear XSM7224S User Manual Page 340

  • Download
  • Add to my manuals
  • Print
  • Page
    / 579
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 339
ProSafe XSM7224S Managed Stackable Switch CLI Manual, Software Version 9.0
Utility Commands 6-16
v1.0, November 2010
show running-config interface
This command shows the current configuration on a particular interface. The interface could be a
physical port or a virtual port—like a LAG or VLAN. The output captures how the configuration
differs from the factory default value.
show sysinfo
This command displays switch information.
show tech-support
Use the show tech-support command to display system and configuration information when
you contact technical support. The output of the show tech-support command combines the
output of the following commands:
show version
show sysinfo
Format show running-config interface {<unit/slot/port>} | VLAN <id> | LAG <id>}
Mode Interface Config
Format show sysinfo
Mode Privileged EXEC
Term Definition
Switch
Description
Text used to identify this switch.
System Name Name used to identify the switch.The factory default is blank. To configure the system
name, see “snmp-server” on page 7-47.
System Location Text used to identify the location of the switch. The factory default is blank. To configure
the system location, see “snmp-server” on page 7-47.
System Contact Text used to identify a contact person for this switch. The factory default is blank. To
configure the system location, see “snmp-server” on page 7-47.
System Object ID The base object ID for the switch’s enterprise MIB.
System Up Time The time in days, hours and minutes since the last switch reboot.
MIBs Supported A list of MIBs supported by this agent.
Page view 339
1 2 ... 335 336 337 338 339 340 341 342 343 344 345 ... 578 579

Comments to this Manuals

No comments