Netgear GS728TP User Manual Page 524

  • Download
  • Add to my manuals
  • Print
  • Page
    / 530
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 523
Configuration Examples
524
ProSafe M5300 Switch
If you do not specify a root bridge and all switches have the same Bridge Priority value,
the switch with the lowest MAC address is elected as the root bridge (see
CST
Configuration on page 146).
5. From the CST Port Configuration screen, select ports 1/0/1 - 1/0/8 and select Enable from
the STP Status menu (see
CST Port Configuration on page 148).
6. Click APPLY.
7. Select ports 1/0/1 - 1/0/5 (edge ports), and select Enable from the Fast Link menu.
Since the edge ports are not at risk for network loops, ports with Fast Link enabled
transition directly to the Forwarding state.
8. Click APPLY.
You can use the CST Port Status screen to view spanning tree information about each
port.
9. From the MST Configuration screen, create a MST instances with the following settings:
MST ID: 1
Priority: Use the default (32768)
VLAN ID: 300
For more information, see MST Configuration on page 151.
10. Click ADD.
11. Create a second MST instance with the following settings
MST ID: 2
Priority: 49152
VLAN ID: 500
12. Click ADD.
In this example, assume that Switch 1 has become the Root bridge for the MST instance 1,
and Switch 2 has become the Root bridge for MST instance 2. Switch 3 has hosts in the
Sales department (ports 1/0/1, 1/0/2, and 1/0/3) and in the HR department (ports 1/0/4 and
1/0/5). Switches 1 and 2 also have hosts in the Sales and Human Resources departments.
The hosts connected from Switch
2 use VLAN 500, MST instance 2 to communicate with the
hosts on Switch 3 directly. Likewise, hosts of Switch 1 use VLAN 300, MST instance 1 to
communicate with the hosts on Switch 3 directly.
The hosts use different instances of MSTP to effectively use the links across the switch. The
same concept can be extended to other switches and more instances of MSTP.