Netgear 700 Series Managed Switch for Software v2.1 User Manual

Browse online or download User Manual for Computer Accessories Netgear 700 Series Managed Switch for Software v2.1. NETGEAR 700 Series Managed Switch for Software v2.1 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 152
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
SM-10004-02
SM-10004-02
June 2003
NETGEAR, Inc.
4500 Great America Parkway
Santa Clara, CA 95054 USA
Phone 1-888-NETGEAR
700 Series Managed Switch
Users Guide for Software
v2.1
Page view 0
1 2 3 4 5 6 ... 151 152

Summary of Contents

Page 1 - User’s Guide for Software

SM-10004-02SM-10004-02June 2003NETGEAR, Inc.4500 Great America Parkway Santa Clara, CA 95054 USAPhone 1-888-NETGEAR700 Series Managed Switch User’s Gu

Page 2 - Technical Support

SM-10004-02viii ContentsRJ-45 Plug and RJ-45 Connectors ... B-6Conclusion ...

Page 3

700 Series Managed Switch User’s Guide for Software v2.16-10 Command Line InterfaceSM-10004-02SystemThe show system command displays system-related da

Page 4

700 Series Managed Switch User’s Guide for Software v2.1Command Line Interface 6-11SM-10004-02Trunk Id Ports-------- -------------------------

Page 5 - Contents

700 Series Managed Switch User’s Guide for Software v2.16-12 Command Line InterfaceSM-10004-02<VLAN index #> = The VLAN ID. Adding the VLAN ID t

Page 6

700 Series Managed Switch User’s Guide for Software v2.1Command Line Interface 6-13SM-10004-02FSM726(config)# diffserv <DSCP> <priority>Wh

Page 7

700 Series Managed Switch User’s Guide for Software v2.16-14 Command Line InterfaceSM-10004-02When the interface command is properly entered, you will

Page 8

700 Series Managed Switch User’s Guide for Software v2.1Command Line Interface 6-15SM-10004-02<duplex operation> = one of three modes. auto, ful

Page 9

700 Series Managed Switch User’s Guide for Software v2.16-16 Command Line InterfaceSM-10004-02Use the no command to disable mirror.NegotiationThis com

Page 10

700 Series Managed Switch User’s Guide for Software v2.1Command Line Interface 6-17SM-10004-02Where<interface type> = Options for this field inc

Page 11 - About This Guide

700 Series Managed Switch User’s Guide for Software v2.16-18 Command Line InterfaceSM-10004-02SwitchportThe switchport command lets you configure VLAN

Page 12 - SM-10004-02

700 Series Managed Switch User’s Guide for Software v2.1Command Line Interface 6-19SM-10004-02TrunkingPort Trunking is a feature that allows multiple

Page 13 - Chapter 2

About This Guide 1SM-10004-02Chapter 1 About This GuideThank you for purchasing the NETGEAR™ 700 Series Managed Switch.AudienceThis reference manual a

Page 14 - Protocols

700 Series Managed Switch User’s Guide for Software v2.16-20 Command Line InterfaceSM-10004-02StaticThe Static Addresses Table, allows the administrat

Page 15 - SNMP Access

700 Series Managed Switch User’s Guide for Software v2.1Command Line Interface 6-21SM-10004-02SyntaxFSM726(config)# mac-address-table disableMultimedi

Page 16

700 Series Managed Switch User’s Guide for Software v2.16-22 Command Line InterfaceSM-10004-02CommunityYou can create up to eight different community

Page 17

700 Series Managed Switch User’s Guide for Software v2.1Command Line Interface 6-23SM-10004-02NameUse the name command to give a name to the switch. T

Page 18 - Software Upgrade Procedure

700 Series Managed Switch User’s Guide for Software v2.16-24 Command Line InterfaceSM-10004-02Spanning TreeSpanning Tree Protocol (STP) ensures that o

Page 19

700 Series Managed Switch User’s Guide for Software v2.1Command Line Interface 6-25SM-10004-02PriorityUse the priority command to set the STP priority

Page 20

700 Series Managed Switch User’s Guide for Software v2.16-26 Command Line InterfaceSM-10004-02FSM726(config)# system config-tftp ip <IP address>

Page 21 - Chapter 4

700 Series Managed Switch User’s Guide for Software v2.1Command Line Interface 6-27SM-10004-02IP-filter addressThe IP-filter address allows you to ent

Page 22

700 Series Managed Switch User’s Guide for Software v2.16-28 Command Line InterfaceSM-10004-02SyntaxFSM726(config)# system gateway <default gateway

Page 23

700 Series Managed Switch User’s Guide for Software v2.1Command Line Interface 6-29SM-10004-02UsernameUse the username command to create a new user fo

Page 24 - Figure 4-5: Main Menu

700 Series Managed Switch User’s Guide for Software v2.12 About This GuideSM-10004-02Features of the HTML Version of this ManualThe HTML version of th

Page 25 - Main Menu> Status

700 Series Managed Switch User’s Guide for Software v2.16-30 Command Line InterfaceSM-10004-02Warning: The previous image in non-volatile memory will

Page 26

700 Series Managed Switch User’s Guide for Software v2.1Command Line Interface 6-31SM-10004-02SyntaxFSM726(config)# system radius authen-mode [local |

Page 27 - Main Menu> Set-Up

700 Series Managed Switch User’s Guide for Software v2.16-32 Command Line InterfaceSM-10004-02Stat-ResetUse the Stat-Reset command to reset all of the

Page 28

Virtual Local Area Network A-1SM-10004-02Appendix AVirtual Local Area NetworkA Local Area Network (LAN) can generally be defined as a broadcast domain

Page 29

700 Series Managed Switch User’s Guide for Software v2.1A-2 Virtual Local Area NetworkSM-10004-02VLAN Behavior in a 700 Series Managed SwitchPackets r

Page 30 - Main Menu> Tools

700 Series Managed Switch User’s Guide for Software v2.1Virtual Local Area Network A-3SM-10004-02To allow untagged packets to participate in the ‘Firs

Page 31 - Main Menu> Security

700 Series Managed Switch User’s Guide for Software v2.1A-4 Virtual Local Area NetworkSM-10004-02

Page 32 - Main Menu> Advanced

Cabling Guidelines B-1SM-10004-02Appendix BCabling GuidelinesThis appendix provides specifications for cables used with a NETGEAR 700 Series Managed S

Page 33

700 Series Managed Switch User’s Guide for Software v2.1B-2 Cabling GuidelinesSM-10004-02Category 5 CableCategory 5 distributed cable that meets ANSI/

Page 34

700 Series Managed Switch User’s Guide for Software v2.1Cabling Guidelines B-3SM-10004-02Table-B-1. Electrical Requirements of Category 5 CableTwisted

Page 35 - Figure 4-18: Port Mirroring

Switch Management Overview 2-1SM-10004-02Chapter 2Switch Management OverviewThis chapter gives an overview of switch management, including the methods

Page 36 - Figure 4-19: Port Trunking

700 Series Managed Switch User’s Guide for Software v2.1B-4 Cabling GuidelinesSM-10004-02Figure B-2 illustrates crossover twisted pair cable.Figure B-

Page 37

700 Series Managed Switch User’s Guide for Software v2.1Cabling Guidelines B-5SM-10004-02Note: Flat “silver satin” telephone cable may have the same R

Page 38

700 Series Managed Switch User’s Guide for Software v2.1B-6 Cabling GuidelinesSM-10004-02Unlike 10BASE-T and 100BASE-TX, which use only two of the fou

Page 39 - Figure 4-25: DiffServ

700 Series Managed Switch User’s Guide for Software v2.1Cabling Guidelines B-7SM-10004-02Figure B-4 shows the RJ-45 plug and RJ-45 connector.Figure B-

Page 40 - Figure 4-27: VLANS

700 Series Managed Switch User’s Guide for Software v2.1B-8 Cabling GuidelinesSM-10004-02Table-B-3. 100/1000 Mbps RJ-45 Plug and RJ-45 Connector Pin A

Page 41 - Figure 4-29: VLAN Membership

802.1x Port-Based Authentication Overview C-1SM-10004-02Appendix C802.1x Port-Based Authentication OverviewThis appendix provides an overview of802.1x

Page 42 - Figure 4-31: Spanning Tree

700 Series Managed Switch User’s Guide for Software v2.1C-2 802.1x Port-Based Authentication OverviewSM-10004-021. The client sends an EAP-start messa

Page 43

700 Series Managed Switch User’s Guide for Software v2.1802.1x Port-Based Authentication Overview C-3SM-10004-02Initial 802.1x communications begin wi

Page 44

700 Series Managed Switch User’s Guide for Software v2.1C-4 802.1x Port-Based Authentication OverviewSM-10004-02

Page 45 - Figure 4-34: MAC

SM-10004-02Glossary1GlossaryUse the list below to find definitions for technical terms used in this manual.10BASE-T The IEEE specification for 10 Mbps

Page 46

700 Series Managed Switch User’s Guide for Software v2.12-2 Switch Management OverviewSM-10004-02Table 2-1. Comparing Switch Management MethodsFor a m

Page 47

700 Series Managed Switch User’s Guide for Software v2.12 GlossarySM-10004-02also Reverse ARP (RARP) which can be used by a host to discover its IP ad

Page 48 - Figure 4-39: SNMP Management

700 Series Managed Switch User’s Guide for Software v2.1Glossary3SM-10004-02Capacity planningDetermining whether current solutions can satisfy future

Page 49

700 Series Managed Switch User’s Guide for Software v2.14 GlossarySM-10004-02Domain NameA descriptive name for an address or group of addresses on the

Page 50

700 Series Managed Switch User’s Guide for Software v2.1Glossary5SM-10004-02Filtering The process of screening a packet for certain characteristics, s

Page 51 - Chapter 5

700 Series Managed Switch User’s Guide for Software v2.16 GlossarySM-10004-02Ranges of addresses are assigned by Internic, an organization formed for

Page 52 - Web Based Management Overview

700 Series Managed Switch User’s Guide for Software v2.1Glossary7SM-10004-02MD5MD5 creates digital signatures using a one-way hash function, meaning t

Page 53 - System Information

700 Series Managed Switch User’s Guide for Software v2.18 GlossarySM-10004-02Port monitoringThe ability to monitor the traffic passing through a port

Page 54 - Status Menus

700 Series Managed Switch User’s Guide for Software v2.1Glossary9SM-10004-02Spanning Tree Protocol (STP)A protocol that finds the most efficient path

Page 55 - Status > Switch Statistics

700 Series Managed Switch User’s Guide for Software v2.110 GlossarySM-10004-02WANA long distance link used to extend or connect remotely located local

Page 56

Index 1Numerics802.1x Port-Based Authentication 3-14, 4-22AAddress Aging 3-25Admin field 3-9Advanced Security 3-14, 4-20, 4-24Advanced Tools 4-20

Page 57 - Status > Port Statistics

700 Series Managed Switch User’s Guide for Software v2.1Switch Management Overview 2-3SM-10004-02Virtual Terminal ProtocolsA virtual terminal protocol

Page 58 - Status > Error Statistics

2 IndexCLI Configure System Restore 5-28CLI Configure System Save 5-28CLI Configure System Stat-Reset 5-32CLI Configure System Username 5-29CLI Co

Page 59 - Status > Most Active Ports

Index 3Inbound Errors 4-6Inbound Non-unicast Packet rate 4-5Inbound Non-unicast Packets 4-6Inbound Octet Rate 4-5Inbound Octets 4-6Inbound Unicas

Page 60 - Status > Port Settings

4 IndexSNMP> Host Table 4-39SNMP> Trap Setting 4-40SNMP> Trap Settings 3-29Spanning Tree 3-22Spanning Tree > Port Setting 4-34Spannin

Page 61 - Status > MAC Address Table

700 Series Managed Switch User’s Guide for Software v2.12-4 Switch Management OverviewSM-10004-02This management method requires the SNMP agent on the

Page 62 - Set-up Menu

700 Series Managed Switch User’s Guide for Software v2.1Switch Management Overview 2-5SM-10004-02

Page 63 - Set-up> IP Configuration

Software Upgrade Procedure 3-1SM-10004-02Chapter 3 Software Upgrade ProcedureAs networking technology advances, NETGEAR will release new versions of t

Page 64 - Set-up> Port Configuration

700 Series Managed Switch User’s Guide for Software v2.1Software Upgrade Procedure 3-2SM-10004-025. Restart the system via the Tools>Reset command.

Page 65 - Set-up> GBIC

2SM-10004-02NETGEAR, INC.www.NETGEAR.comTechnical SupportPlease register to obtain technical support. Please retain your proof of purchase and warrant

Page 66 - Tools Menu

700 Series Managed Switch User’s Guide for Software v2.13-3 Software Upgrade ProcedureSM-10004-02

Page 67

Administration Console Telnet Interface 4-1SM-10004-02Chapter 4 Administration Console Telnet InterfaceThe administration console is an internal, char

Page 68 - Security> Passwords

700 Series Managed Switch User’s Guide for Software v2.14-2 Administration Console Telnet InterfaceSM-10004-02Examples of terminal-emulation programs

Page 69 - Advanced Options

700 Series Managed Switch User’s Guide for Software v2.1Administration Console Telnet Interface 4-3SM-10004-024. When the following screen appears, ma

Page 70

700 Series Managed Switch User’s Guide for Software v2.14-4 Administration Console Telnet InterfaceSM-10004-02There are several characteristics to the

Page 71

700 Series Managed Switch User’s Guide for Software v2.1Administration Console Telnet Interface 4-5SM-10004-02Main Menu> System This screen display

Page 72

700 Series Managed Switch User’s Guide for Software v2.14-6 Administration Console Telnet InterfaceSM-10004-02Figure 4-7: Switch StatisticsMain Menu&

Page 73

700 Series Managed Switch User’s Guide for Software v2.1Administration Console Telnet Interface 4-7SM-10004-02Figure 4-9: Address Manager: MAC Addres

Page 74

700 Series Managed Switch User’s Guide for Software v2.14-8 Administration Console Telnet InterfaceSM-10004-02IP Assignment Mode. The user manually en

Page 75 - Advanced > Port Trunking

700 Series Managed Switch User’s Guide for Software v2.1Administration Console Telnet Interface 4-9SM-10004-02Figure 4-12: Port ConfigurationAdmin fi

Page 76

SM-10004-023Regulatory Compliance InformationThis device is restricted to indoor use due to reduce the potential for harmful interference to co-channe

Page 77 - Advanced> Advanced Tools

700 Series Managed Switch User’s Guide for Software v2.14-10 Administration Console Telnet InterfaceSM-10004-02Gigabit Ports. For the gigabit ports on

Page 78

700 Series Managed Switch User’s Guide for Software v2.1Administration Console Telnet Interface 4-11SM-10004-02After making changes to any of the info

Page 79

700 Series Managed Switch User’s Guide for Software v2.14-12 Administration Console Telnet InterfaceSM-10004-02Figure 4-15: Security Note: Using teln

Page 80 - Advanced> VLANS

700 Series Managed Switch User’s Guide for Software v2.1Administration Console Telnet Interface 4-13SM-10004-02• Port Trunking: a feature that allows

Page 81 - Figure 5-32: Primary VLAN

700 Series Managed Switch User’s Guide for Software v2.14-14 Administration Console Telnet InterfaceSM-10004-02Main Menu> Advanced> Advanced Sec

Page 82

700 Series Managed Switch User’s Guide for Software v2.1Administration Console Telnet Interface 4-15SM-10004-02802.1x port-based authentication provid

Page 83 - Advanced> Spanning Tree

700 Series Managed Switch User’s Guide for Software v2.14-16 Administration Console Telnet InterfaceSM-10004-02Figure 4-19: Port TrunkingTrunks can b

Page 84

700 Series Managed Switch User’s Guide for Software v2.1Administration Console Telnet Interface 4-17SM-10004-02Note: Only the console menu will let yo

Page 85 - Advanced> MAC

700 Series Managed Switch User’s Guide for Software v2.14-18 Administration Console Telnet InterfaceSM-10004-02• Last Saved option. The system will bo

Page 86

700 Series Managed Switch User’s Guide for Software v2.1Administration Console Telnet Interface 4-19SM-10004-02There are two means to differentiate tr

Page 87

SM-10004-024

Page 88 - Advanced> SNMP

700 Series Managed Switch User’s Guide for Software v2.14-20 Administration Console Telnet InterfaceSM-10004-02There are 64 different tags available.

Page 89

700 Series Managed Switch User’s Guide for Software v2.1Administration Console Telnet Interface 4-21SM-10004-02Figure 4-28: VLAN AdministrationTo add

Page 90

700 Series Managed Switch User’s Guide for Software v2.14-22 Administration Console Telnet InterfaceSM-10004-02Figure 4-30: PVID SettingsThis screen

Page 91 - Command Line Interface

700 Series Managed Switch User’s Guide for Software v2.1Administration Console Telnet Interface 4-23SM-10004-02Figure 4-32: Spanning Tree: Bridge Set

Page 92

700 Series Managed Switch User’s Guide for Software v2.14-24 Administration Console Telnet InterfaceSM-10004-02Table 4-1. STP Port Setting ParametersF

Page 93

700 Series Managed Switch User’s Guide for Software v2.1Administration Console Telnet Interface 4-25SM-10004-02Figure 4-34: MACMain Menu> Advanced

Page 94

700 Series Managed Switch User’s Guide for Software v2.14-26 Administration Console Telnet InterfaceSM-10004-02Main Menu> Advanced> Multimedia S

Page 95

700 Series Managed Switch User’s Guide for Software v2.1Administration Console Telnet Interface 4-27SM-10004-02Figure 4-37: Static Multicast Administ

Page 96

700 Series Managed Switch User’s Guide for Software v2.14-28 Administration Console Telnet InterfaceSM-10004-02Main Menu> Advanced> SNMPFigure 4

Page 97 - FSM726# show running-config

700 Series Managed Switch User’s Guide for Software v2.1Administration Console Telnet Interface 4-29SM-10004-02These community strings need to be set

Page 98

Contents iiiSM-10004-02ContentsChapter 1 About This GuideAudience ...

Page 99

700 Series Managed Switch User’s Guide for Software v2.14-30 Administration Console Telnet InterfaceSM-10004-02

Page 100

Web-Based Management Interface 5-1SM-10004-02Chapter 5 Web-Based Management InterfaceYour NETGEAR 700 Series Managed Switch provides a built-in browse

Page 101

700 Series Managed Switch User’s Guide for Software v2.15-2 Web-Based Management InterfaceSM-10004-02Web Based Management OverviewThe 6 menu options a

Page 102 - Configure

700 Series Managed Switch User’s Guide for Software v2.1Web-Based Management Interface 5-3SM-10004-02System InformationFigure 5-2: System information

Page 103 - 33 high

700 Series Managed Switch User’s Guide for Software v2.15-4 Web-Based Management InterfaceSM-10004-02These parameters are not editable from this scree

Page 104 - command

700 Series Managed Switch User’s Guide for Software v2.1Web-Based Management Interface 5-5SM-10004-02Status > Switch StatisticsThe Switch Statistic

Page 105

700 Series Managed Switch User’s Guide for Software v2.15-6 Web-Based Management InterfaceSM-10004-02• Outbound Non-unicast Packet Rate: Transmitted n

Page 106

700 Series Managed Switch User’s Guide for Software v2.1Web-Based Management Interface 5-7SM-10004-02Status > Port StatisticsFigure 5-5: Port Stat

Page 107

700 Series Managed Switch User’s Guide for Software v2.15-8 Web-Based Management InterfaceSM-10004-02• Outbound Discards: Transmitted and is being dis

Page 108

700 Series Managed Switch User’s Guide for Software v2.1Web-Based Management Interface 5-9SM-10004-02Status > Most Active PortsFigure 5-7: Error S

Page 109

SM-10004-02iv ContentsMain Menu> Advanced> Advanced Security ...3-14Main Menu> Advance

Page 110

700 Series Managed Switch User’s Guide for Software v2.15-10 Web-Based Management InterfaceSM-10004-02Status > Reset StatisticsFigure 5-8: Statist

Page 111

700 Series Managed Switch User’s Guide for Software v2.1Web-Based Management Interface 5-11SM-10004-02• Link: A green triangle pointing up indicates a

Page 112

700 Series Managed Switch User’s Guide for Software v2.15-12 Web-Based Management InterfaceSM-10004-02Set-up MenuThere are four kinds of configuration

Page 113

700 Series Managed Switch User’s Guide for Software v2.1Web-Based Management Interface 5-13SM-10004-02This page will allow access to the system inform

Page 114

700 Series Managed Switch User’s Guide for Software v2.15-14 Web-Based Management InterfaceSM-10004-02Click Apply to change the IP settingsSave Config

Page 115

700 Series Managed Switch User’s Guide for Software v2.1Web-Based Management Interface 5-15SM-10004-02• Flow Control: Indicates whether Flow Control s

Page 116

700 Series Managed Switch User’s Guide for Software v2.15-16 Web-Based Management InterfaceSM-10004-02Tools MenuThe Tools page contains functions to m

Page 117

700 Series Managed Switch User’s Guide for Software v2.1Web-Based Management Interface 5-17SM-10004-02After making any changes to the screens within t

Page 118

700 Series Managed Switch User’s Guide for Software v2.15-18 Web-Based Management InterfaceSM-10004-02Tools> Device Reset Figure 5-19: Device Rese

Page 119

700 Series Managed Switch User’s Guide for Software v2.1Web-Based Management Interface 5-19SM-10004-02The user name and password can be up to 20 chara

Page 120

Contents vSM-10004-02Status > Switch Statistics ...4-5Status

Page 121

700 Series Managed Switch User’s Guide for Software v2.15-20 Web-Based Management InterfaceSM-10004-02• Port Trunking• Virtual Cable Tester• Advanced

Page 122 - Stat-Reset

700 Series Managed Switch User’s Guide for Software v2.1Web-Based Management Interface 5-21SM-10004-02• Traffic Management (CoS): Class of Service (Co

Page 123 - Virtual Local Area Network

700 Series Managed Switch User’s Guide for Software v2.15-22 Web-Based Management InterfaceSM-10004-02Advanced > Disable Advanced AlertingFigure 5-

Page 124

700 Series Managed Switch User’s Guide for Software v2.1Web-Based Management Interface 5-23SM-10004-02Figure 5-23: Advanced Security802.1x port-based

Page 125

700 Series Managed Switch User’s Guide for Software v2.15-24 Web-Based Management InterfaceSM-10004-02Advanced > Advanced SecurityFigure 5-24: Adv

Page 126

700 Series Managed Switch User’s Guide for Software v2.1Web-Based Management Interface 5-25SM-10004-02Advanced > Port MirroringFigure 5-25: Figure

Page 127 - Cabling Guidelines

700 Series Managed Switch User’s Guide for Software v2.15-26 Web-Based Management InterfaceSM-10004-02Port Trunking is a feature that allows multiple

Page 128 - Category 5 Cable

700 Series Managed Switch User’s Guide for Software v2.1Web-Based Management Interface 5-27SM-10004-02Advanced> Advanced Tools Use the advanced too

Page 129 - Twisted Pair Cables

700 Series Managed Switch User’s Guide for Software v2.15-28 Web-Based Management InterfaceSM-10004-02This option requires the same setup as the Net o

Page 130 - Patch Panels and Cables

700 Series Managed Switch User’s Guide for Software v2.1Web-Based Management Interface 5-29SM-10004-02Advanced > Traffic ManagementTraffic manageme

Page 131 - Cabling Guidelines B-5

SM-10004-02vi ContentsAdvanced> Spanning Tree > Port Settings ...4-34Advanced> MAC ...

Page 132 - Patch Cables

700 Series Managed Switch User’s Guide for Software v2.15-30 Web-Based Management InterfaceSM-10004-02Advanced > Traffic Management > Broadcast

Page 133 - Cabling Guidelines B-7

700 Series Managed Switch User’s Guide for Software v2.1Web-Based Management Interface 5-31SM-10004-02Advanced> VLAN> Primary VLANFigure 5-32:

Page 134 - Conclusion

700 Series Managed Switch User’s Guide for Software v2.15-32 Web-Based Management InterfaceSM-10004-02Click Apply.Add a port to a VLAN GroupUnder the

Page 135 - Appendix C

700 Series Managed Switch User’s Guide for Software v2.1Web-Based Management Interface 5-33SM-10004-02Advanced> Spanning TreeThis switch is complia

Page 136

700 Series Managed Switch User’s Guide for Software v2.15-34 Web-Based Management InterfaceSM-10004-02Hello Time Time between configuration messages

Page 137

700 Series Managed Switch User’s Guide for Software v2.1Web-Based Management Interface 5-35SM-10004-02Table 5-1. STP Port Setting ParametersFastlink i

Page 138

700 Series Managed Switch User’s Guide for Software v2.15-36 Web-Based Management InterfaceSM-10004-02Advanced> MAC> Address AgingFigure 5-36:

Page 139 - Glossary

700 Series Managed Switch User’s Guide for Software v2.1Web-Based Management Interface 5-37SM-10004-02Any system, whose MAC address and the port numbe

Page 140 - 2 Glossary

700 Series Managed Switch User’s Guide for Software v2.15-38 Web-Based Management InterfaceSM-10004-02• Enable. The system will detect IGMP queries, r

Page 141

700 Series Managed Switch User’s Guide for Software v2.1Web-Based Management Interface 5-39SM-10004-02• 4-Group RMON (RFC1757)Advanced> SNMP> Co

Page 142 - 4 Glossary

Contents viiSM-10004-02SNMP Server ...5-21Spanning Tre

Page 143

700 Series Managed Switch User’s Guide for Software v2.15-40 Web-Based Management InterfaceSM-10004-02The SNMP Host Table screen allows you to add and

Page 144 - 6 Glossary

Command Line Interface 6-1SM-10004-02Chapter 6Command Line InterfaceThe 700 Series Managed Switch features a Command Line Interface (CLI) designed for

Page 145

700 Series Managed Switch User’s Guide for Software v2.16-2 Command Line InterfaceSM-10004-02Once you see the root prompt, you are in CLI mode. If you

Page 146 - 8 Glossary

700 Series Managed Switch User’s Guide for Software v2.1Command Line Interface 6-3SM-10004-02<IP Address> = the IP address of the destination ho

Page 147

700 Series Managed Switch User’s Guide for Software v2.16-4 Command Line InterfaceSM-10004-02FSM726# show diffservAn example of the partial output is

Page 148 - 10 Glossary

700 Series Managed Switch User’s Guide for Software v2.1Command Line Interface 6-5SM-10004-02 0 Packet Discards, 0 Packet ErrorsIPThe show IP

Page 149 - Numerics

700 Series Managed Switch User’s Guide for Software v2.16-6 Command Line InterfaceSM-10004-02Multicast-StaticThe show mac-address-table multicast-stat

Page 150

700 Series Managed Switch User’s Guide for Software v2.1Command Line Interface 6-7SM-10004-02Running-ConfigThe show running-config command displays th

Page 151

700 Series Managed Switch User’s Guide for Software v2.16-8 Command Line InterfaceSM-10004-02 no shutdown speed 100 duplex full flow-ctrl negotiation

Page 152

700 Series Managed Switch User’s Guide for Software v2.1Command Line Interface 6-9SM-10004-02VLAN1 Spanning tree enabled protocol IEEE ROOT ID Pr

Comments to this Manuals

No comments